FD120 Intumescent Seal Specification
Intumescent Seal Specification for FCW120 Door Leaves Installed in Timber Frames
Location | Size and Position |
Stiles/jambs |
FORZA PVC-seals |
Head |
FORZA PVC-seals |
Base |
FORZA Flex-seal |
Square meeting stiles |
FORZA PVC-seal |
Interface between overpanel and frame/transom |
FORZA PVC-seal |
Intumescent Seal Specification for FCH120 Door Leaves Installed in Timber Frames
Location | Size and Position |
Stiles/jambs |
2 no 20 x 4mm H120 PVC cased seals fitted 5mm either side of the centre line in the frame reveal |
Head |
1 no 15 x 2mm H120 PVC cased seal centrally fitted in the leaf head |
Leaf vertical edges |
1no 15 x 2mm H120 PVC cased seal centrally fitted in the leaf edge underneath the outer lipping |
Bottom edge of leaf |
1 no 38 x 2mm H120 PVC cased seal fitted centrally in the bottom edge of the leaf |